13 November 2026 · 9 min read
Harmonised standards explained: why the version matters
How presumption of conformity works, how to read the Official Journal list, and why a test report to a superseded standard can leave a hole in your file.
By The Conformery Team
Photo: Photo by Wesley Tingey on Unsplash
Your lab report says "tested to EN 62368-1" and you assume that settles it. It may not. The same standard number can exist in several editions, and only some of them are the version the EU recognises. The edition on your report decides whether you can lean on the law's shortcut, or whether you have to prove compliance the long way.
This guide explains that shortcut, how to find the current version for your product, and what happens when the version on a test report is old.
The shortcut: presumption of conformity
EU product laws such as the Low Voltage Directive, the EMC Directive and the Radio Equipment Directive set essential requirements in general terms. They say, for example, that equipment must be safe or must not cause harmful interference. They do not say how to test for it.
Harmonised standards fill that gap. They are technical standards written by the European standardisation bodies (CEN, CENELEC and ETSI) at the request of the European Commission. When the Commission cites a standard in the Official Journal of the European Union, products that comply with it are presumed to meet the essential requirements the standard covers. That is the presumption of conformity.
Three points follow from that:
- Standards are voluntary. You can meet the essential requirements another way. But then you must show how, and you lose the presumption.
- The presumption is limited to what the standard covers. A safety standard says nothing about radio spectrum.
- The presumption depends on the citation. A standard that is published by CENELEC but not cited in the Official Journal does not create a presumption under that directive.
Why the route changes for radio products
For the RED, the choice matters more. Our regulation record says self-assessment (Annex II) is available for Article 3(2) and 3(3) requirements only when harmonised standards covering them have been applied in full. If the standards are not applied, only partly applied, or do not exist, you must use EU-type examination by a notified body, or full quality assurance. So a version problem on a radio product is not only a documentation problem. It can decide whether you were allowed to self-assess at all.
For the LVD and EMC Directive, the routes are different. Our record says the LVD only provides self-assessment and the EMC Directive allows an optional notified body route. Still, without a cited standard, you carry the burden of showing that your tests prove the essential requirements are met.
How the Official Journal list works
The Commission publishes the references of harmonised standards through implementing decisions. Each decision has an annex listing, for every standard:
- the reference and title of the standard;
- the reference of the standard it replaces, if any;
- the date on which the presumption of conformity for the replaced standard ceases.
That last column is the one people miss. When a new edition arrives, the old edition does not vanish on the same day. There is usually a transition. After the date of cessation, a product that relies on the old edition no longer benefits from the presumption.
A decision can also add restrictions. A standard may be cited with a notice saying the presumption does not apply to certain clauses or situations. The OJ entry, not the standard's cover page, is the final word.
Four real examples from our regulation records
1. A superseded safety standard. For audio, video, information and communication equipment, our LVD record says EN 62368-1 replaced EN 60950-1 and EN 60065 from 20 December 2020. A report issued after that date to EN 60950-1 is a report to a standard that no longer gives the shortcut for products placed on the market afterwards.
2. An edition-specific citation. Our EMC record lists EN 55032:2015 together with its A11:2020 amendment for multimedia emissions, and EN 55035:2017 for immunity, both cited under Commission Implementing Decision (EU) 2019/1326. The year and the amendment are part of the citation. A report to a later or earlier edition has to be checked against the current list.
3. A version in the radio record. Our RED record lists EN 300 328 V2.2.2, cited via Commission Implementing Decision (EU) 2022/2191, for Wi-Fi and Bluetooth in 2.4 GHz. A spectrum report that cites a different version is a flag, not necessarily a failure, but you need to ask.
4. A standard that exists before the shortcut does. EN 18031-1, -2 and -3 are dated 2024. They were added to the list by Commission Implementing Decision (EU) 2025/138, published on 30 January 2025, and the presumption arises from the date the references were published in the Official Journal. A cybersecurity report finished before that date was real, but it did not carry the presumption until the citation appeared. See EN 18031 explained for the restrictions in that citation.
Why an old version on a test report matters
An old version is not the same as a failed product. The tests may still show the product is safe. What changes is the legal footing, and three things follow.
You lose the presumption for that requirement. Your report no longer proves compliance by itself. You need to demonstrate equivalence another way, usually with a gap analysis from the lab.
You may lose the self-assessment route. For radio products, this can turn a self-declared product into one that needed a notified body.
Your documents contradict each other. If the declaration cites the current standard and the report cites an older edition, a reviewer sees a mismatch. This is what stops many marketplace uploads. See our Amazon compliance documents checklist.
What to do about an old edition
| Situation | What it means | Practical response |
|---|---|---|
| Report cites the current cited edition | Presumption applies for the clauses covered | Record the full reference in the file and declaration |
| Report cites an older edition, still in transition | Presumption may still apply until the cessation date | Note the date of cessation. Plan a retest before it |
| Report cites an edition whose presumption has ceased | No presumption from that report | Ask the lab for a gap analysis against the current edition, or retest |
| Report cites a standard not cited in the OJ | No presumption under that directive | Treat as supporting evidence only. Consider the notified body route for radio |
| Report cites the current standard but the OJ entry has restrictions | Presumption excludes the restricted cases | Check whether your product falls in a restricted case before declaring |
The date that generally matters is when you place the product on the market, not when you ordered the tests. For stock that ships over many months, that date can cross a cessation date partway through a production run. Ask your lab to confirm which edition applies to each batch.
A short routine you can run
1. List every standard on your declaration of conformity with its year and amendment. 2. Find the current Commission list for the directive. For radio equipment, the Commission's radio equipment page links to the current implementing decision. 3. Compare each reference, and check the column showing the date of cessation of presumption for any replaced edition. 4. Read any restrictions or notices attached to the entry. 5. Compare your test reports with your list. Write down any difference. 6. Re-run the routine before each new production batch and after each Commission update.
Our regulation records mark some standards as "verify" because the cited version changes. That is the honest state of the law. The list moves, so do not hard-code a version in a template and forget it.
When there is no harmonised standard
Some requirements have no cited standard. Then you may use other technical specifications, international standards or your own test methods, and document why they achieve the essential requirement. That is a legitimate path, but you carry the burden of proof, and for radio equipment it moves you to a notified body. It is worth asking your lab early whether any of your requirements fall into this group.
Next steps
If your factory has sent test reports, start with how to check a CE test report. For a quick read on a single document, the free evidence check lists the standards and editions it finds and flags the ones to confirm. If you have a whole set of documents to reconcile, Conformery's Product Pack checks each one against the current harmonised standards and tells you which editions need attention. To see which directives apply to your product in the first place, try the requirements checker.
Frequently asked questions
Are harmonised standards mandatory?
No. They are voluntary technical specifications. Applying a standard cited in the Official Journal gives you a presumption that you meet the essential requirements it covers. If you choose another route you must demonstrate compliance yourself, and for radio equipment that can require a notified body.
Where do I find the current list of harmonised standards?
The European Commission publishes references in implementing decisions in the Official Journal, and keeps pages per directive on the single market website. Check the annex for the standard, the standard it replaces and the date the presumption ceases for the replaced edition.
My report cites an older edition. Is my product non-compliant?
Not necessarily. The product may still meet the essential requirements, but the older report may no longer give you the presumption. Ask the lab for a gap analysis against the current edition or a retest, and do not list the old edition on your declaration as if it were current.
Sources
Not sure which rules apply to you?
Answer a few honest questions about your product and see every applicable regulation for the EU, UK and US, each linked to its official source.
Check your requirementsRelated reading
CE marking requirements explained: the 20-minute version
What CE marking actually certifies, which directives apply to your product, and the steps from technical file to Declaration of Conformity.
EU authorised representative, explained: who actually needs one
Why EU product law requires an economic operator established in the Union for many products, what an authorised representative does, and when an importer covers it instead.
REACH Compliance Explained: SVHC and Your Duties
REACH covers almost every chemical in almost every product sold in the EU. Here is what the SVHC Candidate List means, when the 0.1% duty kicks in, and how it differs from RoHS.