13 November 2026 · 9 min read
EN 18031 explained: parts 1, 2 and 3 under the RED
What EN 18031-1, -2 and -3 cover, which radio products need which part, and the restrictions in the Official Journal that can force a notified body.
By The Conformery Team
Photo: Photo by Compare Fibre on Unsplash
Your lab quote has a line that says "EN 18031 cybersecurity assessment" and you do not know whether you need part 1, part 2, part 3 or all of them. Another supplier says you do not need any, because your product only uses Bluetooth. A third says you need a notified body.
This post explains what the three parts cover, which products fall under which, and the restrictions attached to the Official Journal citation, which are where most surprises come from. Everything below is based on our regulation record for the Radio Equipment Directive (RED) and on Commission Implementing Decision (EU) 2025/138.
Where EN 18031 comes from
Since 1 August 2025, certain radio equipment placed on the EU market has had to meet cybersecurity essential requirements in the RED. Commission Delegated Regulation (EU) 2022/30 activated three of them in Article 3(3):
- point (d): the equipment does not harm the network or its functioning, and does not misuse network resources in a way that degrades service;
- point (e): the equipment has safeguards to protect personal data and privacy;
- point (f): the equipment supports protection from fraud.
The harmonised standards that go with those requirements are EN 18031-1, EN 18031-2 and EN 18031-3. They were added to the list of harmonised standards for the RED by Commission Implementing Decision (EU) 2025/138, which was published in the Official Journal on 30 January 2025 and entered into force on the day of publication.
A short and important update: Delegated Regulation (EU) 2022/30 is being repealed by Commission Delegated Regulation (EU) 2026/339, with effect from 11 December 2027, the date the Cyber Resilience Act applies in full. The repeal does not affect market surveillance of radio equipment placed on the market between 1 August 2025 and 10 December 2027 against these requirements. So for products you place on the market now, EN 18031 is the relevant standard. See CRA and RED in one technical file for how the two fit together.
The three parts
The titles below are those listed in the Decision's annex.
| Standard | Title | RED point |
|---|---|---|
| EN 18031-1:2024 | Common security requirements for radio equipment, Part 1: internet connected radio equipment | 3(3)(d) |
| EN 18031-2:2024 | Part 2: radio equipment processing data, namely internet connected radio equipment, childcare radio equipment, toys radio equipment and wearable radio equipment | 3(3)(e) |
| EN 18031-3:2024 | Part 3: internet connected radio equipment processing virtual money or monetary value | 3(3)(f) |
Part 1: network protection
This is the base layer for internet-connected radio equipment. If your product connects to the internet, directly or through other equipment, point (d) is the first requirement to check. Typical products: smart plugs, cameras, routers, speakers, thermostats and hubs.
Part 2: personal data and privacy
This covers radio equipment that processes personal data. It extends beyond internet-connected equipment to childcare radio equipment, toy radio equipment and wearable radio equipment, even where those are not internet connected. A baby monitor, a connected toy and a fitness band are the usual examples.
Part 3: fraud and monetary value
This is for internet-connected equipment that handles virtual money or monetary value, such as payment terminals or devices that hold or transfer value. Most consumer hardware does not need it.
Which parts does my product need?
Work through it in this order.
1. Does it intentionally transmit or receive radio waves? If not, the RED does not apply, and neither does this. 2. Is it internet-connected? The test is whether the equipment can communicate over the internet, directly or through other equipment. If yes, you need Part 1. Devices that only talk to a phone over Bluetooth are a grey area, because the phone may be the route to the internet. Ask your lab or notified body for a written view for your architecture. 3. Does it process personal data, or is it childcare, toy or wearable radio equipment? If yes, add Part 2. A camera account, microphone, voice command, location or health data points here. 4. Does it handle money or monetary value? If yes, add Part 3.
| Product | Likely parts | Why |
|---|---|---|
| Wi-Fi smart plug with an account | 1 and 2 | Internet-connected, processes account data |
| Wi-Fi security camera | 1 and 2 | Internet-connected, images and audio are personal data |
| Bluetooth-only baby monitor | 2 | Childcare radio equipment, even without internet |
| Connected toy with a microphone | 2, plus 1 if internet-connected | Toy radio equipment, voice data |
| Smartwatch | 2, plus 1 if internet-connected | Wearable radio equipment |
| Payment terminal | 1, 2 and 3 | Internet-connected, personal data, monetary value |
Use this as a first pass only. The scoping depends on the architecture and the wording of the delegated regulation, which your assessor should confirm.
The restrictions in the Official Journal
Here is the part that changes your route. Our RED record says self-assessment is available for the Article 3(3) requirements only when harmonised standards covering them have been applied in full, and that notified body involvement is needed where the published restrictions on EN 18031 apply to your product.
The annex of Decision (EU) 2025/138 attaches notices to each standard:
- All three parts: the "rationale" and "guidance" sections of the standard confer no presumption of conformity.
- All three parts, the password restriction: no presumption applies if, when applying clauses 6.2.5.1 and 6.2.5.2, the user is allowed not to set and use any password. For part 1 this is tied to point (d), for part 2 to point (e) and for part 3 to point (f).
- Part 2, the parental control restriction: for the childcare, toy and wearable classes covered by clauses 6.1.3 to 6.1.6, no presumption applies if parental or guardian access control is not ensured when applying the corresponding sub-clauses (6.1.3.4.2, 6.1.4.4.2, 6.1.5.4.2 and 6.1.6.4.2).
- Part 3, an extra restriction: no presumption of conformity with point (f) applies as regards the assessment criteria in clause 6.3.2.4. Our record notes that notified body involvement is required for financial-asset functionality.
Read the decision text itself for the exact wording. The consequence is practical. If your product ships with no default password and lets the user skip setting one, you cannot rely on the standard for that requirement, and the self-assessment route is not available for it. A product that forces the user to set a unique password at setup, or ships with a unique per-device credential, avoids the restriction.
A worked example: a Wi-Fi camera
A brand sells a Wi-Fi indoor camera with a phone app and cloud storage. The first set-up screen offers "Skip" on the password step, because the team wanted a smoother onboarding.
- Parts needed: 1 and 2.
- The skip button means the user may not set a password. That brings the password restriction into play for both parts, so the standards do not give a presumption for those clauses.
- The route moves from internal production control to EU-type examination by a notified body, or full quality assurance.
The fix is a design change: remove the skip and require a unique password, or provision a unique credential per device. That is a software change that can cost much less than a notified body review. This is why you should read the restrictions before design freeze, not after the lab report.
What the lab will ask for
Expect requests for an architecture description, a list of interfaces and network services, how authentication works, how updates are delivered, how personal data is stored and sent, and what happens at factory reset. They test against the assessment criteria in the standard. Ask the lab which edition of the standard it works to and confirm it matches the citation. See harmonised standards explained.
Your test report should say which parts were applied, which restrictions were checked, and which firmware version was tested. A report that only says "EN 18031 passed" is not enough to rely on.
What comes after December 2027
The CRA's Annex I requirements include all elements of the RED points (d), (e) and (f), according to the recitals of the repeal regulation. That is why 2022/30 is going. How EN 18031 will be treated under the CRA is a matter for future standardisation and Commission decisions, and we do not assume the answer. What we can say is that the evidence you build now, such as the risk assessment, authentication design and update process, is the same evidence the CRA asks for. See the CRA compliance checklist.
Next steps
Check your product against the free CRA scope check and the requirements checker to see which regimes it triggers. If you want one file that covers RED cybersecurity under EN 18031, the CRA and the other CE directives, Conformery's CRA Pack handles it, including firmware written by an ODM. See also the regulation pages for the RED and the CRA.
Frequently asked questions
Is EN 18031 mandatory?
The standard is voluntary. Applying it, as cited in the Official Journal and within its restrictions, gives a presumption of conformity with the RED cybersecurity requirements and allows self-assessment. If you do not apply it fully, or a restriction applies, you need an EU-type examination by a notified body or full quality assurance.
Do I need all three parts of EN 18031?
No. Part 1 covers internet-connected radio equipment, Part 2 covers equipment processing personal data including childcare, toy and wearable equipment, and Part 3 covers equipment handling monetary value. Most connected consumer products need Part 1 and Part 2, and few need Part 3.
What happens to EN 18031 when the Cyber Resilience Act applies?
Delegated Regulation (EU) 2022/30 is repealed with effect from 11 December 2027, when the CRA applies in full. Radio equipment placed on the market between 1 August 2025 and 10 December 2027 stays subject to market surveillance against the RED requirements. How EN 18031 will be treated under the CRA has not been settled in the sources we checked.
Sources
Not sure which rules apply to you?
Answer a few honest questions about your product and see every applicable regulation for the EU, UK and US, each linked to its official source.
Check your requirementsRelated reading
CE marking requirements explained: the 20-minute version
What CE marking actually certifies, which directives apply to your product, and the steps from technical file to Declaration of Conformity.
EU authorised representative, explained: who actually needs one
Why EU product law requires an economic operator established in the Union for many products, what an authorised representative does, and when an importer covers it instead.
REACH Compliance Explained: SVHC and Your Duties
REACH covers almost every chemical in almost every product sold in the EU. Here is what the SVHC Candidate List means, when the 0.1% duty kicks in, and how it differs from RoHS.