Academy

13 November 2026 · 9 min read

How to check a CE test report from your factory

A factory test report only helps if it covers your product. Seven checks: model, standard version, lab, dates, scope, configuration and signatures.

By The Conformery Team

An engineer's workbench with an oscilloscope and a printed circuit board, the setting where a CE test report is produced

Photo: Photo by Axel Richter on Unsplash

Your factory has sent a PDF called "CE test report" and says you are good to go. You open it and see forty pages of graphs, a lab logo and the word PASS on the last page. That is not yet proof that your product meets the law.

A report is evidence about one specific sample, tested to one specific standard, on one specific date. It becomes useful to you only if those three things match the product you are about to sell. Most of the bad reports we see are not fake. They are real reports for a different model, an older standard or a narrower scope than the factory implied.

This guide gives you seven checks you can run in about half an hour with no lab experience. They apply to reports for the Low Voltage Directive, the EMC Directive and the Radio Equipment Directive, which cover most consumer electronics. You build the technical file around these reports, so errors here carry straight through to your declaration of conformity.

Why you are the one who has to check

For most electronics, you assess conformity yourself using internal production control. Our regulation record for the LVD says the route is self-assessment with no notified body. The EMC Directive works the same way for most products. The Radio Equipment Directive allows self-assessment only where you have applied the relevant harmonised standards in full.

That means nobody reviews the report before you sign the declaration. The factory, the lab and the trading company that sold you the report carry no legal duty for your declaration. You do. If a market surveillance authority or a marketplace reviewer finds that the report does not match the product, the problem lands on the brand owner.

Check 1: does the report name your exact model?

Find the product identification block, usually on page one or two. Compare it, character by character, with:

  • the model number on your label and in your listing;
  • the model number on your declaration of conformity;
  • the variant names in your own spec sheet.

Look for a trailing letter that differs, a different colour code, or a "series" name that covers several products. A report for model X200 does not cover X200-Pro if the Pro has a different power supply, radio module or antenna. If the factory says the products are "the same electronics", ask the lab for a variant statement or a short delta report. Do not accept a verbal assurance.

Also check the manufacturer name and address. If the report is issued to the factory's customer for another brand, you are holding someone else's evidence.

Check 2: which version of the standard did they test to?

This is the check most buyers skip. Standards have editions, amendments and sometimes a corrigendum. The legal presumption of conformity attaches to the version cited in the Official Journal, not to the number alone. We explain the mechanism in harmonised standards explained.

For each standard in the report, write down the full reference, including year and any amendment. Then compare it with the current harmonised list. The European Commission keeps lists by directive, for example the radio equipment page.

Our regulation records give a few concrete anchors:

  • Safety for audio, video, information and communication equipment: EN 62368-1. Our LVD record notes it replaced EN 60950-1 and EN 60065 from 20 December 2020. A new report to EN 60950-1 is a flag.
  • EMC for multimedia equipment: EN 55032 (EN 55032:2015 with A11:2020 cited) for emissions and EN 55035 (EN 55035:2017 cited) for immunity.
  • 2.4 GHz Wi-Fi and Bluetooth spectrum: EN 300 328, with V2.2.2 cited under Commission Implementing Decision (EU) 2022/2191.

Check the current citation for your own standards before you rely on any of these, because the lists change. If the report cites an older edition, ask the lab whether the delta between editions was assessed. Sometimes a short gap analysis closes it. Sometimes you need a retest.

Check 3: is the lab accredited, and for this test?

The directives that use self-assessment do not require the tests to come from an accredited laboratory. They make you responsible for the result. In practice, an accredited lab gives you much stronger evidence, and anyone reviewing your file will look for it.

What to check:

  • The report carries an accreditation body logo or statement, for example UKAS or A2LA, and an accreditation number.
  • The accreditation standard is ISO/IEC 17025, the general standard for testing and calibration laboratories.
  • The accreditation scope lists the test standard you need. A lab can be accredited for EMC and not for radio spectrum.
  • The accreditation is current and covers the site where the test happened.

To verify, do not trust the logo. Use the ILAC MRA signatory search to find the accreditation body, then follow its directory of accredited facilities. UKAS and A2LA both publish public directories where you can search by lab name and read the scope schedule. If you cannot find the lab, ask the factory for the lab's accreditation certificate and schedule, then check that certificate with the body that issued it.

A test house with a nice website, no accreditation and a very low price is not automatically wrong. It does mean the report needs more scrutiny from you, not less.

Check 4: do the dates make sense?

Collect four dates: sample received, tests performed, report issued, and the date of the standard edition. Then ask:

  • Were the tests done after the product design was frozen? A report that predates a change of power supply or radio module may not represent what you now ship.
  • Is the report issued after the test dates and before the declaration date you plan to sign?
  • Was the edition used still valid for presumption of conformity on the day you place the product on the market?
  • Is the report from a lab accreditation period that was valid on the test date?

Dates that cannot be reconciled are a common sign of a recycled report.

Check 5: does the scope cover every requirement?

A single product can need several tests. The most common gap is a report that covers EMC but nothing else. The table shows what a typical connected consumer device needs and what to look for.

RequirementTypical standard familyWhat the report should show
Electrical safety (RED 3.1a or LVD)EN 62368-1 for AV and ICT equipmentSafety report or CB-style evidence for the exact adapter and product
EMC (RED 3.1b or EMC Directive)EN 55032, EN 55035, EN 301 489 series for radioEmissions and immunity, with the radio EMC part if radio is present
Radio spectrum (RED 3.2)EN 300 328 for 2.4 GHzPer-radio tests for each band and technology
Cybersecurity (RED 3.3 d, e, f from 1 August 2025)EN 18031 seriesAssessment against the right part, with attention to restrictions
Human exposure to RFA standard cited for RED 3.1aSAR or RF exposure evidence where the product is body-worn or close to the body

Read the "summary of tests" page and match each row to a requirement your product triggers. If the product has Wi-Fi and the report has no spectrum test, the report is incomplete. If the product is internet-connected, ask whether anyone assessed the cybersecurity requirements under the RED. Our RED versus EMC explainer shows why a radio product cannot rely on an EMC-only report.

Check 6: was the tested sample the product you sell?

Read the test configuration section. It should list the exact firmware version, the power supply, cables, accessories, and the operating modes used. A passed EMC test with the product in standby does not tell you much about it streaming over Wi-Fi.

Photos in the report should show your enclosure, label position and PCB. If the report shows a development board in a bare case and your product has a plastic shell and a metal logo plate, ask about the differences. Firmware matters too. For radio products, the tested firmware sets power levels and channels, so a later update can change results.

Check 7: is it a real, complete, signed report?

Check the unglamorous things:

  • Page numbering is continuous, for example "page 4 of 41", and no pages are missing.
  • A unique report number appears on every page, and the same one appears in the file name.
  • A named engineer and a reviewer or authoriser have signed or approved it.
  • Annexes referenced in the main text are actually attached.
  • Any disclaimers match what the report claims. "Test results apply only to the sample tested" is normal and is exactly why Check 1 and Check 6 matter.

If the factory sends a bare certificate and not the full report, treat it as a summary. You need the full report for the technical file.

A worked example

A seller buys a Bluetooth speaker from a factory. The factory sends three documents, and the buyer runs the checks.

DocumentFindingAction
EMC report, model SP-20Model on label is SP-20B. Report has no radio EMC part. Standards cited with year and amendment, matching the current list.Ask the lab for a variant statement for the B model. Request EN 301 489 results.
Safety reportTested to EN 60950-1, dated 2022.Flag. This standard was replaced by EN 62368-1 from 20 December 2020 in our record. Ask for a report to EN 62368-1 or a gap analysis.
Spectrum reportLab accreditation logo present, but the lab is not found in its accreditation body's directory.Ask for the accreditation schedule. Verify the scope covers EN 300 328 before accepting.

Three documents, three different problems. None looked wrong at a glance. Each would have left a hole in the technical file, and the hole would have appeared at the worst moment, such as a listing review or an inspection.

What to do when a check fails

Write the finding down in plain words, send it to the factory, and ask for one of three outcomes: a corrected report, a variant or delta statement from the lab, or a retest. Keep the exchange. If you cannot get a fix, you have two honest options: commission your own test from an accredited lab, or do not claim conformity for that requirement.

Do this before you print labels and book freight. A fix before production costs an email. A fix after a listing is suspended costs sales.

Next steps

If you want a second opinion on a single document, upload it to the free evidence check and read the findings report. It reads the document and flags standard versions, model mismatches and dates for you to confirm. For a whole file, Conformery's Product Pack reads every document the factory sent and checks them against each other, so a mismatched model or an old standard shows up before you build the declaration. You can also start with the requirements checker to see which regimes your product triggers, and read what goes in a technical file for the rest of the file.

Frequently asked questions

Does my test lab have to be accredited for CE marking?

For self-assessment routes such as the LVD and EMC Directive, the law does not require the tests to come from an accredited lab. You remain responsible for the evidence, so an ISO/IEC 17025 accredited lab with the right scope is the safer choice, and reviewers often expect it.

Can I use a test report that is a few years old?

Possibly. A report does not expire on its own, but it only supports your declaration if the standard edition is still valid for presumption of conformity and the product has not changed in ways that affect the result. Check both before you rely on it.

What if the report covers a similar model but not mine?

Ask the lab for a variant statement or a delta report that explains the differences and why the results still apply. If the electronics, radio or power supply differ, expect a partial or full retest. Do not put a model on your declaration that the evidence does not name.

Sources

  1. 01European Commission: harmonised standards for radio equipment
  2. 02ILAC: MRA signatory search
  3. 03Radio Equipment Directive 2014/53/EU
  4. 04EMC Directive 2014/30/EU

Not sure which rules apply to you?

Answer a few honest questions about your product and see every applicable regulation for the EU, UK and US, each linked to its official source.

Check your requirements

Related reading