13 November 2026 · 9 min read
GPSR risk assessment: what it must cover, with an example
What the General Product Safety Regulation expects in an internal risk analysis, how to structure one, and a worked example for a battery-powered product.
By The Conformery Team
Photo: Photo by BENCE BOROS on Unsplash
A marketplace has asked for your product safety documentation, or a customs officer has asked for your technical file, and what you have is a CE declaration and a factory test report. Neither one answers the question "what could go wrong with this product and what did you do about it?"
Since 13 December 2024, the General Product Safety Regulation, (EU) 2023/988, expects manufacturers to answer that question in writing. This guide sets out what the internal risk analysis must cover, a structure you can reuse, and a worked example you can adapt.
What the regulation actually asks for
Our regulation record for the GPSR summarises the manufacturer duty, which comes from Article 9. Before placing a product on the market, you carry out an internal risk analysis. You also draw up technical documentation that contains, at minimum, a general description of the product and its key safety-relevant characteristics. Where relevant, it also covers the risk analysis, the measures you took to reduce risk, and the standards you applied.
You must keep that documentation up to date, give it to market surveillance authorities on request, and retain it for 10 years after the product was placed on the market.
The GPSR is a safety net. Where sector law such as the Low Voltage Directive, the Radio Equipment Directive or the Toy Safety Directive covers a risk, that law takes precedence for that risk. The GPSR picks up what is left, and adds duties around traceability, online selling and recalls. There is no notified body and no conformity marking under the GPSR. The risk analysis is the conformity assessment.
What you have to think about
Article 6 sets out the aspects to take into account when judging whether a product is safe. Based on the regulation text, they include:
- the product's characteristics, including its composition and design;
- its packaging, instructions for assembly, installation, use and maintenance;
- its effect on other products, where it is reasonably foreseeable it will be used with them;
- the categories of consumers using it, in particular vulnerable consumers such as children, older people and persons with disabilities;
- the appropriate cybersecurity features necessary to protect the product against external influences, where the product's nature requires it and an external influence could affect safety;
- the evolving, learning and predictive functionalities of the product, where the nature of the product requires it.
The regulation also says that being able to make a product safer, or the existence of a lower-risk product, does not by itself make your product dangerous. You are not required to build the safest product imaginable. You are required to show that you identified the hazards and reduced them as far as reasonable for the product and its users.
The regulation does not prescribe a scoring method. You choose one and apply it consistently. A simple severity-by-likelihood matrix is fine for most consumer products.
A structure that works
A risk analysis that an authority can follow has six parts.
1. Product description. Model, variants, intended use, foreseeable misuse, target users, and the environments it will be used in. 2. Users and exposure. Who will use it, who else is exposed (children in the house, pets), how often and for how long. 3. Hazard identification. Mechanical, thermal, electrical, chemical, fire, radiation, ergonomic, software or connectivity related. Use incident data to prompt you. The EU Safety Gate portal lists dangerous products reported by Member States, and searching it for similar products is a cheap way to find hazards you have not thought of. 4. Risk estimation. For each hazard, rate the severity of harm and the likelihood. Record your scale. 5. Risk reduction. Design changes, guards, warnings, instructions, packaging, testing. Design out the hazard first, then protect against it, then warn. 6. Residual risk and conclusion. What remains after the controls, and why you consider it acceptable. Record the evidence: tests, standards, supplier declarations.
Add a review date and a change log. If a complaint, accident report or design change touches a hazard, the analysis needs updating.
Where this meets CE paperwork
If your product is CE-marked, your technical file may already contain a risk assessment, as the LVD and RED technical documentation requirements expect one. Do not write a second, conflicting document. Use one risk assessment and make sure it covers both the CE risks and the GPSR extras: vulnerable users, packaging, instructions, foreseeable misuse and traceability. See what goes in a technical file for how the pieces fit.
A worked example: a USB-rechargeable handheld fan
This is an illustration, not a real product file. Take a handheld fan with a lithium-ion cell, charged over USB at 5V, sold on marketplaces. It comes with a wrist lanyard and is marketed for summer travel and festivals.
First, which laws apply? The charger is a separate item with its own rules. The fan itself runs at 5V DC, which is below the 75V DC lower limit of the Low Voltage Directive in our record, so the LVD does not cover it. EMC and the Battery Regulation still apply, and so does the GPSR for general safety. That makes the GPSR risk analysis the main safety document for the fan body.
| Hazard | Who is exposed | Severity | Likelihood | Controls | Residual risk |
|---|---|---|---|---|---|
| Finger contact with blades | All users, children in particular | Medium | Medium | Fine-mesh guard, tested with a finger probe, blade tip speed limited | Low |
| Cell overheating during charging | All users | High | Low | Protection circuit, certified cell, charge current limit, test report for the cell | Low |
| Lanyard strangulation | Young children | High | Low | Breakaway clip on the lanyard, warning in the manual, age warning on pack | Low |
| Hair caught in the guard | All users | Medium | Medium | Guard aperture size, warning in the manual | Low to medium |
| Small parts released after a drop | Children under 3 | High | Low | Screwed enclosure, drop test, not marketed for children under 3, warning | Low |
| Misuse: used while charging | All users | Medium | Medium | Charging inhibits motor, instruction and symbol | Low |
Notice what the table shows. Each row names a hazard, a person, a rating, a control and what is left. The conclusion is a short paragraph saying why the remaining risks are acceptable and which test reports and standards support that. Each control points to evidence: the finger probe test, the cell report, the drop test. Without the evidence, the table is only your opinion.
Two rows exist because of Article 6. The lanyard and small-parts rows only appear if you ask who else might use the fan. A fan sold at festivals and on holiday will end up in children's hands, so the analysis has to say so and deal with it. An analysis written only for an adult buyer would miss both.
Connected products need more
If the product connects to a phone or the internet, add rows for the connected hazards: loss of a safety function if the connection drops, a remote command that overheats the product or opens a lock, or a software update that changes behaviour. Article 6 points to cybersecurity features and to evolving functions where they matter for safety. For radio products, the RED cybersecurity requirements and, from 2027, the Cyber Resilience Act add further obligations. See the CRA and RED technical file.
Mistakes we see
- Copying a generic template. An authority will notice the same risk table on a kettle and a keyboard.
- Ignoring children. If children can reach it, assess for them.
- Only warnings as controls. Warnings are the last step in the hierarchy, not the first.
- No evidence links. Each control should point at a test, a standard or a design drawing.
- Never reviewed. A complaint that changes a hazard rating needs a documented update.
- No traceability. The product needs a type, batch or serial number, and the manufacturer's name and address, on the product, packaging or accompanying document. Our GPSR for online sellers guide has the operator duties.
What to do next
Start with a one-page product description and a list of hazards. Rate them honestly, then decide the controls, then collect the evidence. If you want help assembling the whole file, Conformery's Product Pack drafts the risk assessment from the documents your factory supplied and keeps it consistent with the declaration and labels. To see which laws your product triggers before you start, use the requirements checker.
Frequently asked questions
Does a CE-marked product still need a GPSR risk assessment?
Sector CE legislation takes precedence for the risks it covers, so a good CE risk assessment goes a long way. GPSR duties beyond that still apply to consumer products, including traceability, the responsible economic operator and online selling rules, so check that your single risk assessment covers vulnerable users, instructions and foreseeable misuse.
How long do I have to keep the risk assessment?
The GPSR requires manufacturers to keep the technical documentation, including the risk analysis, for 10 years after the product was placed on the market, and to keep it up to date and available to market surveillance authorities on request.
Is there an official template for a GPSR risk assessment?
The regulation sets what the technical documentation must contain but does not prescribe a template or a scoring method. Any clear structure that identifies hazards, rates risk, records controls and cites evidence can work, as long as you apply it consistently.
Sources
Not sure which rules apply to you?
Answer a few honest questions about your product and see every applicable regulation for the EU, UK and US, each linked to its official source.
Check your requirementsRelated reading
GPSR for online sellers: what changed since December 2024
The General Product Safety Regulation has applied since 13 December 2024. What it means for responsible persons, marketplaces and online listings.
WEEE registration: what online sellers must do
If your product has a plug or a battery, WEEE registration applies country by country. Who needs an authorized representative, and 2026 marketplace rules.
The CRA Reporting Duty Is Live: What Manufacturers Must Do Now
Since 11 September 2026, manufacturers must report actively exploited vulnerabilities and severe incidents within 24 hours. What the CRA's reporting duty requires and what to do now.